SALIENT FEATURES
- Wires – ISI marked wires used having ends shielded.
CAPACITOR TESTING
- Voltage Test
- a) Between Terminals: 1.5 Times of Rated Voltage
- b) Between Body & Terminals: 2000 VAC for 60 secs.
- Endurance Test: 500 hrs. at 1.25 times Rated Voltage
- Tan Delta Measurement Test: 0.002 at 50 Hz.
- LCR Comparison Test
- Charge Discharge test
Applications of?Capacitor-Run Motor
The capacitor-run motors are used for driving loads of high inertia requiring frequent starts where the pull-out torque and the efficiency required are high such as –
- Pumping equipment
- Air compressors
- Refrigerators
- Electric fan
- Exhaust fan,
Please raise your query of product through our email id:??info@indiacitymart.com?or helpline no:?9039034433
Technical Specifications
Product Features
Voltage Available | 440 VAC | Construction | CRC Can |
Dielectric | PP | Termination | Nuts |
Impregnation | PU Resin | Application | 1 Phase? Pump |
Box Size in M.M. | 128x68x180 | Standard Pack | One |